La combinación del sensor de microvariación del tallo + sensor Aranet 4-20mA ofrece una solución inalámbrica completa para el monitoreo de la variación del tallo en invernaderos. El sensor permite investigar los efectos de la tasa de riego y otros factores ambientales sobre el balance hídrico y el crecimiento de las plantas.
El sensor sólo es compatible con las estaciones base de Aranet
Medidas: microvariaciones del tallo
Alcance de la línea de visión: hasta 3 km/ 1.9mi
Entorno operativo: uso en interiores y exteriores
Potencia del transmisor: 14 dBm
Transmisión de datos: 1,2, 5, 10 minutos
Clase de protección: IP64
Salida: 4-20mA
Stem Micro-Variation Sensor SD-5Mi (4-20mA output) | |
Measurements | Stem Micro-Variation |
Measurement range | 0 to 5 mm |
Stem diameter range | 5 to 25 mm |
Output | 4 to 20 mA |
Resolution | < 0.002 mm (w/filter) |
Operating temperature | 0°C to 50°C (32°F to 122°F) |
Supply Voltage | 10 to 30 VDC* |
Power | max 2W |
SD-5M | SD-6M | |
Measurement range | 0 to 5 mm | |
Stem diameter range, mm | 5 to 25 | 20 to 70 |
Sensitivity | 0.4 V/mm (3.2 mA/mm or 4 mA/mm) | |
Output | ||
SD-5/6M | 0 to 2 VDC, linear | |
SD-5/6Mi | 4 to 20 mA | |
Supply voltage | 10 to 30 VDC | |
Power | ||
SD-5/6M | 1.5 W max | |
SD-5/6Mi | 2 W max | |
Noise | < 1 mV w/filter, 1 kHz cutoff | |
Resolution | 0.002 mm (w/filter) | |
Operating temperature | 0 to 50 ℃ | |
Excitation time | 5 s | |
Temperature effect | < 0.02% total stroke/℃ | |
Cable length between probe and signal conditioner | 1 m |
Aranet 4-20mA current Sensor | ||
Measurements | 4-20 mA current | |
Line of Sight Range | 3km/1.9 | |
Operating environment | Indoor and Outdoor use | |
Transmitter power | 14 dBm | |
Frequency | Depends on base station instructions | |
Measurement range | 0 – 30 mA | |
Measurement accuracy | ± 0.5 % | |
Measurement resolution | 0.01 mA | |
Data Transmission | 1, 2, 5, 10 minutes | |
Data Protection | Data encryption | |
Power options | 1 AA Alkaline battery (Zn/Mn02) | |
1 AA Lithium battery (Li/FeS2) | ||
Battery life @20°C/68°F | Up to 7 years with Alkaline battery | |
Up to 10 years with Lithium battery | ||
Operating temperature | -20°C to 55°C/ -4°F to 131°F with Alkaline battery | |
-40°C to 60°C/ -40°F to 140°F with Lithium battery | ||
Operating humidity | 0% – 100% | |
Dimensions | 35mmØ x 120mm/ 1.4inØ4.7in | |
Weight | 82g/2.9oz with Alkaline battery (1m/3.2ft probe) | |
74g/2.6oz with Lithium battery (1m/3.2ft probe) | ||
Construction | ASA Plastic | |
Cable length | 1m/3.2ft | |
Compatible base stations |
Aranet PRO (from sw v1.4) | |
Protection class | IP68 | |
Marking | CE, FCC | |
Included | 1 AA Alkaline battery, string |
* Para los transductores que utilizan 4-20 mA como salida, el software de usuario de la interfaz web de Aranet PRO permite al cliente definir la traducción de los valores de mA detectados a una unidad de medida definida por el usuario.